RESPIRATORY PROTECTION

North Respirators

How To Properly Don Disposable Respirators


1. Untwist straps. Thread bottom strap through bottom buckle and repeat for top strap. Hold respirator in hand with nose contour (narrow end) at fingertips, allowing headstraps to fall below hand.


2. Place respirator under chin with molded nose contour (narrow end) up. Flange must be uncreased inside respirator. Raise top strap to top back of head. Pull shorter bottom strap head, below ears, to around neck. Do not wear with only one strap.


3. Adjust tension on both top and bottom straps to provide a tight and comfortable seal. To tighten, pull ends of straps. To loosen, push open hinge of buckle with thumb and pull on strap.


4. Each time user enters work area the respirator must be seal checked. Cover front of respirator by cupping both hands.
INHALE SHARPLY. A negative pressure should be felt inside respirator. If any leakage is detected at respirator edges, adjust straps by pulling back along the sides and/or reposition the respirator. Repeat until sealed properly, otherwise do not enter work area and see your supervisor. Entry into a contaminated area with an improper fit may result in sickness or death.

3M 6000 Series Respiratory Selection Guide

The following selection guide will help you order the correct components for some typical respiratory protection applications, using 3M Series 6000 Half-Mask Respirators. For more detailed information about your particular application however, call our Sales Department or
3M’s Technical Hotline at 1-800-243-4630.

Cartridge Facepiece With
Cartridge Only
Facepiece With Cartridge,
5010 Prefilter,
and 501 Prefilter Retainer
Facepiece With Cartridge,
2040 HEPA Filter
and 502 Adapter

6001 Organic Vapor Organic Vapors Organic Vapors and Dusts
and Mists
Organic Vapors and Dusts,
Fumes and Radionuclides
6002 Acid Gas Chlorine, Hydrogen
Chloride, Sulfur Dioxide,
and Hydrogen Sulfide
(escape only)
Chlorine, Hydrogen Chloride,
Sulfur Dioxide, Chlorine Dioxide
and Hydrogen Sulfide
(escape only) and Dusts
and Mists
Chlorine, Hydrogen Chloride,
Sulfur Dioxide, Chlorine
Dioxide and Hydrogen Sulfide
(escape only), and Dusts,
Fumes and Mists and
Radionuclides
6003 Organic Vapor/
Acid Gas
Organic Vapors, Chlorine,
Hydrogen Chloride,
Hydrogen, Fluoride
and Sulfur Dioxide
Organic Vapors, Chlorine,
Hydrogen Chloride, Hydrogen
Fluoride and Sulfur Dioxide
and Dusts and Mists
Organic Vapors, Chlorine,
Hydrogen Chloride, Hydrogen
Fluoride and Sulfur Dioxide and
Dusts, Fumes and Mists
and Radionuclides
2040 P100 HEPA Filter Dusts, Fumes, Mists and Radionuclides

Examples of 6000 and 7000 Series Respirators
Dusts, Fumes, Mists and Radionuclides 6000 or 7000 Series Respirator
2091 P100 Hepa Filter
Organic Vapors, Dusts, Mists, Paint,
Lacquer and Pesticides
6000 or 7000 Series Respirator
6001 Organic Vapor Cartridge
5N11 Pre Filter
Organic Vapors 6000 or 7000 Series Respirator
6001 Organic Vapor Cartridge

Organic Vapors and Dusts, Fumes, Mists
and Radionuclides
6000 or 7000 Series Respirator
6001 Organic Vapor Cartridge
2091 P100 Hepa Filter
502 Prefilter Adapter
501 Prefilter Retainer


P14-0299

3M Series 6000 Vapor Cartridges

Series 6000 Filters and Cartridges are designed to be used with 3M 6000 Series facepieces and 7000 Series facepieces that include a bayonet attachment.  Filters and cartridges can be combines to achieve different protection.  For technical assistance, call your Colony representative or 3M's Technical Assistance Hotline:  800-243-4360.

Call for Pricing


P14-0292

3M P100 Particulate Filter

NIOSH approved for environments containing certain oil and non-oil based particles. Use with 3M™ Respirators 5000 Series or 3M™ Cartridges 6000 Series with 3M™ Adapter 502, 3M™ Facepieces 6000 Series, or 3M™ Facepieces 7000 Series with bayonet filter holders.  When properly fitted, use in a variety of applications including welding, brazing, torch cutting, metal pouring, soldering, and exposure to lead, asbestos, cadmium, arsenic, and MDA for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH).  Sold by the pair. 72 pairs per case.

Call for Pricing


P13-9061

3M Pre-Filters

Designed to be used as a Pre-Filter in conjunction with 6000 Series cartridges. Must use with 501 Pre-Filter Retainer. Pre-Filters sold in packages of 10. Retainers sold individually.

Call for Pricing


P14-0923

P100 Multi-Gas & Vapor Cartridge

NIOSH approval: P100/certain organic vapors, chlorine, hydrogen chloride, chlorine dioxide, sulfur dioxide, hydrogen sulfide (escape only), ammonia/methylamine, formaldehyde, or hydrogen fluoride. Please note that OSHA regulations require that gasproof goggles be worn with half facepiece respirators when used against formaldehyde. Sold in packages of 2. Model 60926.

Call for Pricing


P14-2053

3M™ Hydrogen Fluoride Cartridge/Filter with Nuisance Level Organic Vapor and Acid Gas Relief

This cartridge/ filter is NIOSH approved and provides the highest level of protection against oil and non-oil based particles. Use with 3M™ Half and Full Facepieces 6000, 7000 and FF-400 Series with bayonet filter holders.  When properly fitted, use in a variety of applications including welding, brazing torch cutting, metal pouring, soldering and exposure to lead, asbestos, cadmium, arsenic, MDA and HF for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces.

Call for Pricing


P19-0560

Respirator Wipes

Pre-moistened 5” x 7” cleaning towelettes with alcohol made with 70% Isopropyl Alcohol (IPA) for cleaning. Packaged in boxes of 100 with a dispenser cut-out for easy grabbing. Ideal to clean rubber respirator face pieces and other PPE. Made in the USA.

Call for Pricing


P14-0047

Respirator and Equipment Cleaning Wipes

These pre-moistened wipes are alcohol free, individually packaged tissues that are used to clean respirator masks, and other safety equipment such as face shields, hard hats, and hearing protectors. The dispenser holds 100 individually packaged, large 5" x 8" folded wipes.

Call for Pricing